• Other accessory

Other accessory

Fiber-optic Accessory
Brand:Avantes

avantes-accessory.jpg

Applicable fields

UV/Visible/NIR spectrum
Transmission absorption reflection spectrum
Fluorescence spectrum analysis
Energy gap defect analysis
LED Luminosity Analysis
radiological analysis
Colorimetric analysis
On-site monitoring of vacuum system coating procedures
Geology and mineral analysis applications
Online process monitoring
LIBS spectrum
Raman spectroscopy
Chemometry




01.jpg

Cuvette Sample Holders


The standard colorimetric sample cell can accommodate a standard 10mm x 10mm colorimetric cell and can be used to measure absorbance and measure fluorescence.
Detail





Temperature-Controlled Cuvette Holders


Colorimetric sample holder with magnetic stirrer and semiconductor temperature control device.
Detail




03.jpg

Variable In-Line Filter Holders


When an in-line filter is needed, Avantes offers two types of in-line filter holders: the FH-INLINE-1” and the FH-INLINE. The FH-INLINE-1” is designed to hold one inch filters from 1-60 mm thick. The FH-INLINE is designed for 1/2” or 12-13 mm filters of 1-8 mm thick.
Detail



Direct-Attach Cuvette Holders


To mount a cuvette holder directly to your light source, Avantes offers a range of direct-attached cuvette holders. The CUV-DA connects to the AvaLight-DHc, -XE and -(HP)LED light sources, the CUV-DA-DHS to the AvaLight-DHS and AvaLight-DHS-BAL and the CUV-DA-HAL-Mini to the AvaLight-HAL-Mini. These devices can be used for either absorbance or fluorescence measurements.
Detail


06.jpg

In-Line Fiber-Optic Attenuator


For all UV-VIS-NIR applications and ATT-INL-EXT setups where light intensity must be reduced, Avantes offers the inline fibre-optic attenuator (ATT-INL-EXT) and the direct attached fibre-optic attenuator (ATTDA). This device is an iris attenuator which controls light throughput to avoid detector saturation.
Detail


07.jpg

Direct-Attach Fiber-Optic Attenuator


When light intensity must be reduced, the direct-attached attenuator is a great choice with your AvaLight series light sources. The attenuator helps in situations where detector saturation is an issue. It is attached to the light source and has a SMA connector to couple to other measurement devices and your spectrometer.
Detail


08.jpg

Direct-Attach Cuvette Holder with Attenuator & Filter Holder

Have the most flexible setup with the combined cuvette holder, attenuator, and filter holder. 

Detail


09.jpg

Variable Path Length Cuvette Holders


For low absorption measurements and flow cell cuvettes, the CUV-VAR-UV/VIS cuvette holder is the ideal solution. 
Detail


10.jpg

Integrating Spheres


The integrating sphere is a commonly used component in high-precision spectral optical paths. It can be used as a light collector or a scattered light source.
Detail


11.jpg

Integrating Spheres with Halogen Light Source


The built-in light source integrating sphere has a tungsten halogen lamp placed in the middle of the integrating sphere, which is suitable for reflectance measurement and can also be used as an ideal scattered light source.
Detail


12.jpg

Large Integrating Spheres


Integrating spheres from 100mm to 300mm diameter.
Detail


13.jpg

Variable Collimating Lens Holders


For transmission measurements of samples of various sizes and thicknesses, the variable collimating lens holder is the perfect tool. The vertical bars can be adjusted to samples up to 160 mm thick.
Detail


14.jpg

Optical Post Mount


For easily mounting a collimating lens on a bread-board laboratory table, rail carriers and other bench plates, the Optical Post Mount (OPM) should be used. 
Detail


22.jpg
AvaTripod

The AvaTripod is a flexible and versatile accessory, which is useable in various applications.

Detail


15.jpg
AvaTrigger
Small and sensitive: the AvaTrigger! Designed for use with any AvaSpec-USB2/EVO spectrometer, it enables two different external triggering methods: optical and manual.
Detail



Fiber-Optic Switch

It can control the switching of two optical fiber optical paths (switching of optical signals).

Detail


17.jpg

Fiber-Optic Multiplexer


The optical fiber optical path switch has several input ports and several output ports, and the connection method between the output ports and the input ports can be controlled by a computer.
Detail


18.jpg

In-Line Flow Cells


It can be installed at industrial sites to measure the absorbance of liquid samples online.
Detail


19.jpg

Micro Flow Cells


The micro flow sample cell uses a 1.5mm polytetrafluoroethylene tube to inject samples and can be used for online measurement of absorbance and liquid chromatography (HPLC).
Detail


20.jpg

Reference Tiles


For diffuse reflection measurements, Avantes offers the WS-2 reference tile. The RS-2 is available for specular reflection measurements.
Detail



21.jpg

Power Adapters



Most AvaSpec spectrometers are USB powered, but some users prefer to power their instrument externally. Avantes PS-12V and PS-24V can be used to connect your AvaSpec spectrometer and AvaLight light sources to any 100-240V power connection.
Detail



Related Products

NIRLine Series

NIRLine Series

Fiber & Probe

Fiber & Probe

OEM series

OEM series

CompactLine Series

CompactLine Series

AvaSpec series spectrometer

AvaSpec series spectrometer

SensLine Series

SensLine Series